A common fault analysis of asphalt mixing plant - Cold aggregate supply system fault diagnosis and solution



Fault
Cause
The bottom of the belt is damaged.
The environment temper is too high.
Take measures to cool
Belt tension is insufficient to skid.
Adjust the belt tension
Premature belt breakage
Foreign matter into the bottom of belt.
Adjust the sweeper to ensure effective cleaning
The pressure of sweeper is too large.
Adjust the sweeper balance beam position.
The insufficient belt tension made idling.
Adjust the belt tension.
Belt wear
The roller entrained sediment
Regular inspection and cleaning
Serious non-parallel rollers.
Adjust the parallelism
Belt tension is insufficient
The tension of belt can be adjusted.
belt slippage
Belt tension is insufficient
Adjust the belt tension
Belt with oil
Thoroughly clean
Belt to harden
Generate heat due to belt slippage
Adjust the belt tension
Ambient temperature is too high
Take measures to cool
Belt quiver
The belt is too long
Install the roller in the two axis
Improper belt tension
Properly adjust the belt tension